J.S.Cock · AI Inquiry Demo
← All inquiries · See end-to-end flow →
Inquiry

JT118202 · Artec Aqua AS

VS: Forespørsel Cla-Val ventil
partialNorwegianapplication advice

Original customer email

Recovered from forward chain
Fromknro@artec-aqua.com
SubjectForespørsel Cla-Val ventil
Sentfredag 24. januar 2025 11:34
Attachments
  • · image001.png
  • · image002.gif
  • · image832421.gif
Forwarded by Sortvik, Rene at JS Cock

Structured extraction

{
  "language": "no",
  "intent": "application_advice",
  "customer": {
    "company": "Artec Aqua AS",
    "contact_name": "Knut Ivar Rødset",
    "contact_email": "knro@artec-aqua.com",
    "phone": "+47 99 33 93 93",
    "vat_number": null,
    "address": "Postvegen 13, 6018 Ålesund, Norway"
  },
  "items": [
    {
      "line_no": 1,
      "quantity": 1,
      "unit": "stk",
      "product_reference": "Cla-Val pressure-reducing valve for blending two water sources before filtration; customer asks which Cla-Val variant to use",
      "manufacturer": "Cla-Val",
      "manufacturer_part_no": null,
      "cross_ref_to": null,
      "specs": {
        "dimension": "DN450",
        "pressure_rating": null,
        "material_body": null,
        "material_seal": null,
        "actuation": null,
        "voltage": null,
        "torque_or_flow": null,
        "temperature": null,
        "thread_or_connection": null,
        "other": [
          {
            "key": "inlet_pressure_main",
            "value": "9 bar"
          },
          {
            "key": "inlet_pressure_reserve",
            "value": "2.5 bar"
          },
          {
            "key": "function",
            "value": "pressure reduction on main water source"
          }
        ]
      },
      "missing_fields": [
        "pressure_rating",
        "material_body",
        "material_seal",
        "downstream_target_pressure",
        "flow_rate"
      ]
    }
  ],
  "application_context": "Måsøval Settefisk fish farm at Urke is rebuilding water intake. Two water sources (main 9 bar, reserve 2.5 bar) feed a manifold before filters/heat exchangers/aerator. Customer wants to mix sources upstream of filtration and needs pressure reduction on the main source. Asking for variant recommendation.",
  "attachments_referenced": [],
  "delivery": {
    "location": null,
    "deadline": null,
    "incoterms": null
  },
  "previous_reference": {
    "is_update_of": null,
    "notes": null
  },
  "completeness": "partial",
  "missing": [
    "downstream target pressure",
    "flow rate",
    "delivery location",
    "deadline"
  ]
}

Quote (TILBUD)

Ground-truth oracle
CustomerArtec Aqua AS
Customer no.16195
SalespersonRene Sortvik
Quote date2026-02-03
CurrencyNOK
Total ex. MVA340,353.1 NOK
Delivery termsEXW
Payment termsFri leveringsmåned + 30
Line items · 6
CLA99999
CLA-VAL 90-01-300 10-2 P1: 9BAR P2:2,4BAR - Pressure reducing valve CLA-VAL NGIE-90-01/KCOSX,DN 300/PN16 With one additional 90-01 pilot circuit on the other side
qty 1unit 164,647.1total 164,647.1
CLA99999
DN300 H strainer model 90-501 20-1
qty 1unit 48,000total 48,000
QIF-100-001-0032C
2PC BALL VALVE 1-1/4" BSP THREADED 1000PSI W/ LOCKABLE HANDLE-14NM Leveringstid CLA-VAL 5-6 uker
qty 1unit 341total 341
QIF-110-002-0300
BF-VALVE DN300 PN10 LUG STK-LISTE SQ22XH25 WORM GEAR IP65 CI C5-M/DI GEAR/SS316 PARTS/GREASED
qty 3unit 3,844total 11,532
QIF-110-002-0500
BF-VALVE DN500 PN10 LUG STK-LISTE SQ32XH39 WORM GEAR IP65 CI C5-M/DI GEAR/SS316 PARTS/GREASED
qty 3unit 18,456total 55,368
QIF-180-022-0500
DN500 RUBBER COATED DUAL CHECK VALVE, DI BODY EPDM rubber liner, PN 10, DIN PN 10/16 flanges
qty 3unit 20,155total 60,465