J.S.Cock · AI Inquiry Demo
← All inquiries · See end-to-end flow →
Inquiry

JT123178 · H.L. Skjøng

#TOMO | VS: Forespørsel magnetventil
unusableMixednew inquiry

Original customer email

Recovered from forward chain
Fromerik.k@hlskjong.no
SubjectForespørsel magnetventil
Senttorsdag 19. mars 2026 13:20
Attachments
  • · image002.png
  • · image003.png
  • · image004.png
  • · image005.png
  • · image006.png
  • · image007.gif
  • · image008.png
  • · image659357.gif
Forwarded by Tone Monslaup at JS Cock

Structured extraction

{
  "language": "mixed",
  "intent": "new_inquiry",
  "customer": {
    "company": "H.L. Skjøng",
    "contact_name": "Erik Lund Kråkenes",
    "contact_email": "erik.k@hlskjong.no",
    "phone": "+47 966 01 101",
    "vat_number": null,
    "address": "Breivika Industriveg 48, 6018 Ålesund, Norway"
  },
  "items": [
    {
      "line_no": 1,
      "quantity": null,
      "unit": null,
      "product_reference": "magnetventil (solenoid valve)",
      "manufacturer": null,
      "manufacturer_part_no": null,
      "cross_ref_to": null,
      "specs": {
        "dimension": null,
        "pressure_rating": null,
        "material_body": null,
        "material_seal": null,
        "actuation": null,
        "voltage": null,
        "torque_or_flow": null,
        "temperature": null,
        "thread_or_connection": null,
        "other": []
      },
      "missing_fields": [
        "quantity",
        "unit",
        "manufacturer",
        "manufacturer_part_no",
        "dimension",
        "pressure_rating",
        "material_body",
        "material_seal",
        "voltage"
      ]
    }
  ],
  "application_context": null,
  "attachments_referenced": [],
  "delivery": {
    "location": null,
    "deadline": null,
    "incoterms": null
  },
  "previous_reference": {
    "is_update_of": null,
    "notes": "References potential replacement for previously problematic component; original product/quote not identified"
  },
  "completeness": "unusable",
  "missing": [
    "specific_product_details",
    "quantity",
    "delivery_location",
    "delivery_deadline"
  ]
}

Quote (TILBUD)

Ground-truth oracle
CustomerAFRY Norway AS
Customer no.21189
SalespersonPer Enok Hanssen
Quote date2026-02-06
CurrencyNOK
Total ex. MVA626,801 NOK
Delivery termsEXW
Payment termsFakturadato+15 dager
Line items · 7
FRAKTXXX
FRAKTKOSTNADER FRA PRODUSENT
qty 1unit 0total 0
ILM-4-L50/S01/V/I42
ILM-4-L50/S01/V/I42/P/X/X/X . Inductive Conductivity Meter Measuring ranges: 0...0.5 mS/cm up to 0...999 mS/cm Output: 4...20 mA (Cond. / Temp.) Supply voltage: 18...36 V DC Process Temp.: -10...130°C (150°C max. 60min) With the following configuration: Insertion length L50: 50 mm Process connection S01: CLEANadapt G1" Head orientation V: vertical Output Signal I42: IO-Link, 1x4...20mA Electrical Connection P: cable gland M16x1,5 Interface/Display X: without Display Cap X: Plastic without window Special Configuration X: Standard configuration
qty 7unit 20,475total 143,325
ITM-51
ITM-51/TC2/V/I42/P/X/X/X Turbidity sensor Measurement principle: infrared backscatter method, colorindependent Supply: 18...36 V DC Pressure: -1..20 bar Process temp.: -10..130°C; CIP/SIP 140°C/120Min. Optical: Sapphire With the following configuration: Process connection ITM-51 TC2: Tri-Clamp 2"
qty 7unit 31,390total 219,730
HM-E/050
2IN HM-E050100 TURBIDE FLOWMETER ROTOR: 316l - RANGE: 94-964 L/MIN Turbine Flowmeter Size: DN50 acc. to DIN 11850 Series 2 Rotor: 316L (1.4404) Range: 94 - 964 l/min Pharma-Version
qty 7unit 26,318total 184,226
HTE000
PICK UP PROBE 3-WIRE 70530311364710 Opprinnelsesland:US
qty 7unit 3,630total 25,410
FTS-141/W
FTS-141/X - Flow switch Flow switch calorimetric Process connection: G1/2" CLEANadapt Wetted material: 1.4404 (316L) Process temp.: 0...100°C Output PNP switch max. 200mA Supply 16...32V DC Plastic cap without control window
qty 7unit 7,730total 54,110
NEG99999
ADAPTOR S01->TC2 They want adaptors to all sensors so they can be attached to 2 inch TC
qty 7unit 0total 0