J.S.Cock · AI Inquiry Demo
← All inquiries · See end-to-end flow →
Inquiry

JT124151 · PG Flow Solutions

#HEOL Justering av PER00372
partialNorwegianupdate quote

Original customer email

Recovered from forward chain
Fromkristoffer.tabutiaux@pg-flowsolutions.com
SubjectJustering av PER00372
Sentfredag 10. april 2026 12:02
Attachments
  • · Outlook-ps0qcwsu.png
  • · image210920.gif
Forwarded by Helge Olsen at JS Cock

Structured extraction

{
  "language": "no",
  "intent": "update_quote",
  "customer": {
    "company": "PG Flow Solutions",
    "contact_name": "Kristoffer Vegdal Tabutiaux",
    "contact_email": "kristoffer.tabutiaux@pg-flowsolutions.com",
    "phone": "+47 960 04 460",
    "vat_number": null,
    "address": "Laerumveien 100, N-3074 Sande, Norway"
  },
  "items": [
    {
      "line_no": 1,
      "quantity": 4,
      "unit": "stk",
      "product_reference": "PER00372",
      "manufacturer": null,
      "manufacturer_part_no": null,
      "cross_ref_to": null,
      "specs": {
        "dimension": null,
        "pressure_rating": "8.5 bar",
        "material_body": null,
        "material_seal": null,
        "actuation": null,
        "voltage": null,
        "torque_or_flow": null,
        "temperature": null,
        "thread_or_connection": null,
        "other": [
          {
            "key": "adjustment_service",
            "value": "spring change and pressure adjustment required"
          }
        ]
      },
      "missing_fields": [
        "manufacturer",
        "dimension",
        "material_body",
        "material_seal",
        "actuation",
        "thread_or_connection",
        "temperature"
      ]
    }
  ],
  "application_context": null,
  "attachments_referenced": [],
  "delivery": {
    "location": null,
    "deadline": null,
    "incoterms": null
  },
  "previous_reference": {
    "is_update_of": "202505712",
    "notes": "Adjustment request for 4 units of PER00372 already ordered under this PO; pressure setting was omitted and needs to be set to 8.5 bar"
  },
  "completeness": "partial",
  "missing": [
    "customer_vat_number",
    "delivery_location",
    "original_specification_of_PER00372",
    "technical_confirmation_of_adjustment_feasibility"
  ]
}

Quote (TILBUD)

Ground-truth oracle
CustomerPG FLOW SOLUTIONS AS PG Flow Solutions AS PG FLOW SOLUTIONS AS
Customer no.10044
SalespersonKUN
Quote date2026-04-10
CurrencyNOK
Total ex. MVA14,006 NOK
Delivery termsEXW
Payment termsFakturadato+30 dager
Line items · 4
FRAKTXXX
FRAKTKOSTNADER FRA PRODUSENT TILKOMMER
qty 1unit 750total 750
PER99999
SPRING FOR PER00372
qty 4unit 850total 3,400
PER00372B
BODY SEALKIT FOR DN50 PER00372
qty 4unit 664total 2,656
WRK-SI-02B
RESERTIFISERING SIKKERHETSVENTIL INKL. SERTIFIKAT
qty 4unit 1,800total 7,200